◎ 型号含义 Type meaning
① 可控硅调压 SCR voltage regulator
② 闭环稳压 Closed-loop stabilizer
③ 负载电压 220V 或 380VAC Load voltage 220V or 380VAC
④ 15A,25A,40A,50A,70A,90A,120A,150A,200A
⑤ 控制电压 0-5VDC Control voltage 0-5VDC
⑥ 控制电流 4-20mA Control current 4-20mA
◎ 产品概述 Product overview
◆ 额定电流:15A-200Amps
◆ 额定电压:220V/380VAC(可选)
◆ 无需外接 +12V 直流电源
◆ 增设闭环(负反馈)稳压系统,能有效稳定电压波动
◆ 绝缘介质电压大于 2000VAC
◆ 支持 4-20mA, 0-5V 自动控制模式,也可手动控制,调节平滑
◆ 内置屏蔽电路,抗干扰能力强
◆ 采用大功率晶闸管芯片和 DCB 陶瓷釉锌绝缘底板材料
◆ 性能稳定,可靠性高
◆ Rated current: 15A-200Amps
◆ Rated voltage: 220V/380VAC (optional)
◆ No external +12V DC power supply required
◆ Effectively stabilize voltage fluctuations with closed-loop (negative feedback) voltage regulator system
◆ Insulation voltage greater than 2000VAC
◆ Support automatic control mode (control signal 4-20mA, 0-5V) and manual control mode, and both modes are smooth to adjust
◆ Built-in shielding circuit with strong anti- interference ability
◆ THigh-power thyristor chip, and insulating base plate with DCB ceramic glaze material
◆Stable performance and high reliability
注意 :
1. 当负载电流为 10A 时 , 必须加装散热器 ; 为 40A 及以上时 , 必须加风扇强冷或水冷 .
2. 使用感性负载时 , 务必在输出端并接一个压敏电阻 , 取值为负载电压的 1.6-1.9 倍 .
Notice:
1. If the load current is 10A, a heat sink must be equipped; if the load current is 40A or more, an air-cooled radiator or a water-cooled radiator must be installed.
2. When the load is an inductive load, be sure to connect a varistor in parallel with the output terminal, whose voltage value is 1.6-1.9 times the load voltage.
◎ 安装尺寸及接线图 Installation dimensions and wiring diagram